ケーブリング・クロニクル
You’re Just a Few Clicks Away from Finding Your Right Tool
In our ongoing efforts to enhance your credentials as a network management superstar, we have a new selection gizmo that will make picking the right tool as easy as, well, everything else we help you do.
2013 年 9 月 24 日
Prevent Errors, Limit Complexity and Reduce Cost Associated with Cable Certification
Perhaps the last thing a buyer of cable test equipment thinks about when looking for a product is how to prevent testing errors—and that’s a big mistake. While issues such as cost, standards and specifications including bandwidth and test speeds are important, decision makers should not ignore the issues of project errors and the subsequent delays they can cause.
2013 年 9 月 24 日
ETL 検証の重要性
If you’re in the cable testing business, you should know about ETL Verification.
2013 年 7 月 10 日
2013 年 6 月 17 日
2013 年 6 月 11 日
無料のケーブル・テスト管理ソフトウェア – LinkWare™ の利点を得る
現在のケーブル設備の検証は、1 つの現場で先進的なカテゴリーの 5e テスト・レポートに含まれるデータ・フィールドが 400 をゆうに超えるようになり、検証結果の評価は非常に複雑化しています。何百、何千という数のリンクを含む一般的な作業では、ネットワーク・エンジニアがすべての結果を調べて合格と判断しても、なお重大な問題が残っています。試験仕様やアダプタに誤りがなかったかどうかを調べるにはどうすればよいのでしょうか?すべてのテスターに適切なソフトウェア・バージョンが使用されたでしょうか?期待通りのマージンが得られ、そのマージンは安定していたでしょうか?
2013 年 3 月 28 日
Encircled Flux でマルチモード・テスト精度を高める方法
Anyone who’s ever tested a multimode fiber optic link with light sources from different equipment vendors will know that the loss measurement can vary by as much as 50 percent. 適切なコントロールがなければ、マルチモード光源によるマルチモード・ファイバーへの光の注入に変化が出ます。 同じメーカーの光源であっても異なった立上げ条件の下では、多様なリンク損失が測定され、異なった、そして多くの場合混乱するテスト結果につながります。
2013 年 3 月 11 日
Co-location Data Center Operators Testing Next Generation Cabling.
2013 年 2 月 28 日
OTDR Troubleshooting in the Data Center? ...Yes we can!
The growing demand for higher bandwidth is affecting nearly every industry today, as organizations rely more on applications that support a variety of critical business processes. Whether it’s high-definition video, social media support, electronic medical records or other high-bandwidth applications, companies increasingly are facing a need to support higher capacity data transmission for their employees, customers and business partners. This trend toward greater capacity has in turn created an increased need for high bandwidth fiber optic cabling in the data center.
2013 年 2 月 21 日
Encircled Flux – Encircled Flux とは?気を配らなければならない理由とは?
LC/MPO カセットのような低損失光ファイバー・コンポーネントの導入に伴って、予定損失(テスト制限)はますます小さくなりつつあります。結果として、敷設業者は、ファイバー・テストに関する従来の方法や前提がもはや成立しないことに気付いています。
米国電気通信工業会 (TIA) は、現在もコネクターあたり 0.75 dB を許可していますが、工場で研磨されるコネクターは 0.2 dB 前後です。そのため、敷設業者が TIA の制限をテストする際には、測定にかなりの不確実性が認められています。つまり、このようなテストを実施することは妥当ではあっても完璧ではないということです。
2013 年 2 月 8 日