DTX CableAnalyzer バージョン 2.78 のリリース・ノート

Changes to DTX Version 2.78 (July 2016) 

 

  1. Cable / Spec Database Change
  • Changed TIA-568-C to TIA-568.3-D for fiber testing
    • 850 nm Multimode fiber loss changes from 3.5 dB/km to 3.0 dB/km
    • Added an “OSP (OS2)” option which changes the fiber loss from 0.5 dB/km to 0.4 dB/km
  • For DTX Compact OTDR, three new limits added to help prevent links with poor reflectance passing:
    • ANSI/TIA-568.3-D Link RL = 20 dB
    • ANSI/TIA-568.3-D Link RL = 35 dB
    • ANSI/TIA-568.3-D Link RL = 55 dB
  • For DTX Compact OTDR, “General Fiber” limits renamed/corrected, values do not change:
    • General Fiber RL - 35dB becomes General Fiber RL = 35 dB
    • General Fiber RL - 40dB becomes General Fiber RL = 40 dB
    • General Fiber RL - 55dB becomes General Fiber RL = 55 dB
  • Added Korean Pre-Deploy 250MHz
  • Spezialkabel München changed to SKM Skyline
  • Manufacturer cable types updated/added:
    • Linxcom
    • Dintek
    • GIGANET
    • Berk-Tek
    • EXCEL
    • Maxxam
    • Leviton
    • DIGITUS
    • LANSYST

 

Changes to DTX Version 2.77 (March 2015)

Don't forget to update to LinkWare 9.6 and AxTalk Analyzer 6.2.


1.  Cable / Spec Database Change

  • Changed generic cable  names to match internationally accepted nomenclatures:
    • UTP becomes U/UTP
    • FTP becomes F/UTP
    • STP becomes S/FTP
  • Manufacturer cable types updated/added:
    • ALANTEC
    • AT&T Cabling Systems
    • CCT Premise
    • CORNING Cable Systems
    • DINTEK LAN CABLES
    • Eurolan
    • Furukawa
    • KELine
    • Linxcom
    • METZ CONNECTR (BTR)
    • Nexans
    • QUBIX
    • R&M
    • SOLARIX
    • VOKA Cable
    • Added ISO/IEC 14763-3:2014
    • Added TIA 1005 Cat 6A Channel and TIA 1005 Cat 6A Perm. Link limits
    • Changed TIA Singlemode fiber length limits to 40,000 m
    • Profinet delay skew changed from 50 ns to 20 ns
    • Updated  the following laboratory test limits:
    • ISO C6PCable 100m (LA) Insertion Loss curve
    • ISO C6A Cable Spool (LA) Return Loss curve
    • ISO C5ePCable 100m (LA) Insertion Loss curve
    • ISO C6A PCable 100m (LA) Insertion Loss curve
    • ISO C6A PCable 100m (LA) Return Loss curve
    • ISO C6A Cable 100m (LA) Return Loss curve
    • ISO C6A PCable Spool (LA) Return Loss curve
    • ISO C6 Cable 100m (LA) Insertion Loss curve

2. バグ修正
  • When over-writing an existing fiber test result on the same tester, but using a different fiber module, the serial number and calibration date are not updated - fixed

 

 

Changes to DTX Version 2.74 (March 2013)
 
Don't forget to update to LinkWare 8.0 and AxTalk Analyzer 5.0.

1.  Cable / Spec Database Change

  • Added Korean Pre-Deploy Twisted Pair Test Limit
  • Added LS Cable System and Korean Limits
  • Updated dB rules
  • Updated the following Cable Libraries:
    • SCHNEIDER ELECTRIC
       
      · Are you a manufacturer wanting to add your cables to the DTX/OptiFiber Pro? Click here for details.
       

2. バグ修正

  • 10GBASE-SR loss limit was incorrect at 2.5 dB for OM1 fiber, corrected to 2.4 dB
  • 10GBASE-SR OM3 limit was a duplicate of OM4, fixed back to the correct loss limit and length
  • 10GBASE-LX4 length was incorrect at 5,000m, changed to 10,000 m
  • 10GBASE-L length was incorrect at 5,000m, changed to 10,000 m

 
 
 
 
Changes to DTX Version 2.63 (June 2012)
 

1.  Cable / Spec Database Change

  • 10GBASE-SR now permits up to 400 m, 2.9 dB loss with OM4 cable per IEEE update
  • Added 40GBASE-FR, 40GBASE-LR4, 40GBASE-SR4, 100GBASE-ER4, 100GBASE-LR4, 100GBASE-SR10
  • Added OTDR limits: General Fiber RL -55dB and ISO/IEC 11801-2010 no RL
  • Japan folder name changed to JIS
  • Added Resistance as an information only parameter to Cat 6A patch cord test limits
  • Added LMR600, RG-213 and RG-214 coax cable types
  • Added new Korean Fiber Standards
  • Updated the following Cable Libraries:
    • ACOME
    • AMP NETCONNECT
    • Brand-Rex
    • Coax
    • Corning
    • Draka
    • FibrainDATA
    • Infilink
    • Legrand
    • Panduit
    • Schrack Technik
    • Siemon
    • Superior Essex
    • TE Connectivity

· Are you a manufacturer wanting to add your cables to the DTX/OptiFiber Pro? Click here for details.

2. 新機能

  • Added Outlet Configuration “CSU/DSU” (LinkWare 7.2 required)
  • Added Outlet Configuration “2 x Two-Pair Crossed” (LinkWare 7.2 required)

3. バグ修正

  • Improved “Battery Training” text in German
  • Televes model has unique splash screen
  • Cat 5e patch cord RL star band incorrect at 1 MHz – fixed. Note that no one would ever have seen this issue.


 
 
 
 
Changes to DTX Version 2.52 (June 2011)


1.  Cable / Spec Database Change

  • Renamed Taiwan Cabling Standard from EL-3600-6 to EL-3600-8. (No change in values)
  • Added Korean Cat 6 Channel test limit to Korean folder.
  • Added Japanese fiber standard JIS X5150.
  • Placed ISO Patch Cord Cat 6A standards to the top of the Cat 6A Patch Cord folder
  • Removed all (LA) limits from Cat 6A Patch Cord folder and placed them in Other folder.
  • OM1, OM2, OM3, OM4, OS1 and OS2 put to the top of the cable library:
    • OM1: 62.5 µm with an MBW of 200 MHz.km (Was Multimode 62.5)
    • OM2: 50 µm with an MBW of 500 MHz.km (Was Multimode 50)
    • OM3: 50 µm with an MBW of 2000 MHz.km
    • OM4: 50 µm with an MBW of 4700 MHz.km
       
      Check with your cabling vendor for the correct classification of the cabling you are using.
       
  • Updated the following Cable Libraries:
    • Berk-Tek
    • Excel
    • Gigamedia
    • InfiLink
    • Are you a manufacturer wanting to add your cables to the DTX/OptiFiber? Click here for details.

2. 新機能

  • Increased Folders allowed from 20 to100. (Caution: Due to the nature of the FAT file system for SD/MMCs and other similar memory device such as USB sticks, reading times on the card will increase when you go beyond 20 folders. The reading time increase will depend on which SD/MMC you use. We recommend downloading results on a regular basis and cleaning the card of unused folders)
  • Support for new Cat 5e, 6 and 6A patch cord adapters.

 

3. バグ修正

  • Some AxTalk Analyzer users occasionally observed their units losing communication – fixed.





Changes to DTX Version 2.41 (January 2011)


1.  Cable / Spec Database Change

  • Renamed 10GBASE-S to 10GBASE-SR (Name change only)
  • Added ANSI/TIA-568-C OTDR test limit as Tier 2 testing is now in this standard
  • Added General Fiber RL -35 dB and -40 dB to OTDR test limit options
  • Added ISO/IEC 14763-3 2-Conn OTDR limit (In this standard, the first and last connections should be better than 0.3 dB for multimode and 0.5 dB for singlemode)
  • Added ISO/IEC 14763-3 2-Pigtl OTDR limit (This test limit is used if you have pigtails with fusion splices, so the first and last event loss limits are 0.6 dB for multimode and 0.8 dB for Singlemode)
  • Added M12 Category 5e Patch Cord test capability with DTX-CHA021 M12 Modules
  • Removed Length limit on existing OTDR General Fiber test limit
  • Added OS2 Singlemode cable
  • Added LANMaster cables.
  • Updated Panduit cables.
  • Updated AMP NETCONNECT cables
  • Removed “Fair” from OTDR Port

2. 新機能

  • M12 Patch Cord Testing

 
 

Changes to DTX Version 2.36 (July 2010)


1.  Cable / Spec Database Change

  • Renamed:
    • TIA568C Backbone MM to TIA-568-C Multimode (No change in values).
    • TIA568C Backbone ISP to TIA-568-C Singlemode ISP (No change in values).
    • TIA568C Backbone ISP to TIA-568-C Singlemode OSP (No change in values).
  • Removed draft numbers from ISO/IEC Twisted Pair test limits; AMD2 was published in April 2010 (No change in values).
  • Removed "max" from the ISO/IEC standards to reduce confusion.
  • Replaced:
    • ISO ClassEa Ch AMD1 with ISO11801 Channel Class Ea;
    • ISO ClassF Ch AMD1 with ISO11801 Channel Class F;
    • ISO ClassFa Ch AMD1 with ISO11801 Channel Class Fa because AMD1 and AMD2 Channel values are the same.
  • Added TIA 1005 Industrial Ethernet test limits - supports two pair Category 5e and 6 testing.
  • Change "Method" names for fiber:
    • Method A becomes 2 Jumper.
    • Method B becomes 1 Jumper.
    • Method C becomes 3 Jumper to align with international standards and aid users in selecting the correct option.
       
      Methods vs Jumper
       
  • Added M12 Two-Pair and M12 Two-Pair Crossed to support new TIA 1005 test limits.
  • Updated ZugBus and MVB test limits.
  • Updated the MBW @ 1300 nm for OM3 cable. Was 2000, now 500. Error has no impact on the outcome of test results.
  • Added length as "info" test for Spool Tests using the laboratory adapters.
  • Added Russian copper and fiber standards.
  • Added 10GBASE-LRM .
  • Added OM4 fiber - 10GBASE-S will still fail after 300 m. We are waiting for the IEEE to define the supported distance of 10GBASE-S using OM4 fiber.
     
  • Updated the following Cable Libraries:
    • SYSTIMAX
    • CommScope
    • Panduit
    • Comtran
    • INFRAPLUS
    • Schrack
    • Remee
    • Kerpen/Leoni
    • AMP NETCONNECT
    • DIGILINK
      • Are you a manufacturer wanting to add your cables to the DTX/OptiFiber?">Click here for details.

 

2. 新機能

3. バグ修正

  • Japanese string for Far-End Source corrected.
  • Overwriting a fiber result in the DTX in Smart Remote Mode does not change the Method type if that has also been changed; rare occurrence - fixed.
  • Unterminated far end Spool Test on links between 95 and 99 m could result in excessive NEXT being reported. Has gone undetected until now because Spool Tests involved cable greater than 305 m or 1,000 ft - fixed.
  • Spanish results show PASA/FALLO for PASS/FAIL. Should be "PASA*/FALLO" - fixed.
     

4. Known issues

  • General Fiber length limit for DTX-xFM and DTX-XFM2 users is set to 1,000 m. Should be 2,000 m. This selection for DTX-xFM and DTX-XFM2 users should only be used as a place holder for creating custom fixed loss limits. (Minor issue)
  • None - if you have found an issue, please let us know mailto:support@flukenetworks.com




Changes to DTX Version 2.24 (November 2009)
There is no change to the user with this code. It was issued to the factory to enable new bench test software. If you have Version 2.22, there is no need to update your DTX CableAnalyzer. Doing so will not harm or affect your DTX CableAnalyzer. New DTX CableAnalyzers shipping from the factory here in Everett, WA will have the new 2.24 code.




Changes to DTX Version 2.22 (April 2009)


1.  Cable / Spec Database Change

  • TIA568B Backbone MM changed to TIA568C Backbone MM
  • TIA568B Backbone SM ISP changed to TIA568C Backbone SM ISP
  • TIA568B Backbone SM OSP changed to TIA568C Backbone SM OSP
  • TIA568B Horiz. DELETED (Not in the new ANSI/TIA-568-C.0 standard)
  • Added ACR-N and PS ACR-N to Category 6A AUTOTESTs as Information Only.
  • ISO/IEC 11801 Amendment 2 updated to Draft 25N1599
    • ISO ClassEa PL2 25N1599
    • ISO ClassEa PL2 25N1599 Lo IL
    • ISO ClassEa PL3 25N1599
    • ISO ClassFa PL2 25N1599
    • ISO ClassFa PL3 25N1599

      If your Class EA Permanent Link has two connectors (no consolidation point), then you would select ISO ClassEa PL2 25N1599. If your Class EA Permanent Link has three connectors (includes a consolidation point) then you would select ISO ClassEa PL3 25N1599. ISO ClassEa PL2 25N1599 Lo IL would only be used if ISO ClassEa PL2 25N1599 failed the AUTOTEST.
       
  • ISO11801 CL Ea Qualification added - click here for details
  • Corrected accuracy bands on patch cord certification (users should observe less marginal PASS* reporting)
  • EN50173 updated
    • EN50173 PL2 Class Ea
    • EN50173 PL3 Class Ea
    • EN50173 PL2 Class Fa
    • EN50173 PL2 Class Fa

      If your Class EA Permanent Link has two connectors (no consolidation point), then you would select EN50173 PL2 Class Ea. If your Class EA Permanent Link has three connectors (includes a consolidation point) then you would select EN50173 PL3 ClassEa. Same principle applies to Class FA.
       
  • ISO C7A SE Patch Cord Return Loss Limits now have a minimum floor of 10 dB.
  • Limit TIA C6PCable Spool (LA) had incorrect accuracy curve – updated and fixed.
  • Twisted Pair Class Ea Limits Low IL updated.
  • NVP updated for Cable Type: INFRA + - MNCGM800 / 880
  • Added Daetwyler cable to Cable Library.
  • Update to the Draka Cable Library.
  • Update Hitachi Manchester Cable Library.

 

 

2. 新機能

  • Support for DTX-CLT (Chinese) CableAnalyzer.
  • Support for new GG45 Permanent Link Adapter (Due Q3 2009)

 

3. バグ修正

  • Coax LIA not detected on power-up when NSM or AxTalk module installed- fixed.
  • Noise spike between 351-400 MHz can cause DTX to reset – very rare occurrence - fixed.
  • Incorrect warning "SM fiber attached to MM port" – fixed.
  • DTX occasionally resets when setting launch compensation – fixed.
  • DTX saves plot data intermittently even when Store Plot Data is not selected – fixed.
  • Gainer Events should NOT always get marked with a status of WARNING – fixed.
  • Incorrect compensation causes coax HDTDR to trigger false HDTDR failure at remote – fixed.
  • Incorrect French translation of splices – fixed.
  • Scanning on / off text cut off in Spanish – fixed.
  • OTDR can report end as ghost – fixed.
  • Custom Loss Limit editing causes a crash (rare) – fixed.
  • FindFiber locks up when Coax nose installed – fixed.
  • Fiber Loss allows you to enter 3.25 dB/ km but shows 3.3 dB / km – fixed.
  • Bad Japanese translation for "Current Series" – fixed.
  • Auto OTDR intermittently chooses too large of pulse width – fixed.
  • OTDR Out-of-range for APC ends message – fixed.
  • Method A had three patch cords under Patch Lengths when it should be two – fixed.

4. Known issues






Changes to DTX Version 2.12 (June 2008)

1.  Cable / Spec Database Change

  • All draft numbers have been removed from Category 6A test limits since this standard is now approved.
  • In accordance with cabling standards worldwide
    • ELFEXT becomes ACR-F
    • PSELFEXT becomes PS ACR-F
    • ACR becomes ACR-N
    • PSACR becomes PS ACR-N
    • PSNEXT becomes PS NEXT
  • Added 70 dB rule for ACR-F (all standards)
  • Added 67 dB rule for PS ACR-F (all standards)
  • Folders have been created for Cat 5e, Cat 6, Cat 6A, Cat 7 and Cat 7A patch cord test limits.
  • CLC patch cords standards have been removed from the test database since they are now the same as the ISO/IEC 11801 test limits.
  • Addition of 7 new specifications:
    • ISO Class Fa PL 25N1431
    • EN50173 PL Class Fa
    • JIS X5150:2004 Cl. Fa PL
    • ISO Class Fa Ch FDAM
    • EN 50173 Channel Class Fa
    • JIS X5150:2004 Cl. Fa Channel
    • ISO Class Ea PL 25N1431
  • Added Cat 6A FTP Cable
  • Updated ADC, Draka and SYSTIMAX GigaSPEED cable types to utilize the Cat 6A HDTDR/HDTDX parameters – these cable types were using the Cat 6 HDTDR/HDTDX parameters. This does not affect your PASS/FAIL result.
  • Renamed ‘Berk-Tek’ to LANMark
  • Updated Kerpen, Panduit and Siemon cable types.
  • Changed test limit name “ISO/IEC 14763” to “ISO/IEC 14763-3”
  • Moved “GBxxxx” test limits to a new China folder
  • Added Corning SMF28
  • Updated backscatter coefficient values for the following brands: CommScope, Furukawa, HCS Fiber, Molex AFOxxxx, OFS GigaGuide and LaserWave, TeraGain, Systimax LazrSPEED and OptiSPEED.
  • Updated IR and backscatter coefficient values for OFS LaserWave 150 (50)
  • Updated modal bandwidth values for Corning eSX+ (50) and Corning SX+ (50)

 

2. 新機能

  • Added support the new M12 Channel adapter to be used to test links in the industrial environment that are constructed with the M12 two wire-pair connector. This adapter supports the 10BASE-T, 100BASE-T and Profinet test standards.
  • Added a new test standard in the Application folder called “10G Equip. Channel”. This standard is identical to the 10GBASE-T standard or the TIA TSB155 Channel standards with the exception that the length Pass/Fail decision. This standard requires that the average length of the four wire pair not exceed 100 meter (328 feet).
  • An additional entry has been added to the test standard selection “Last Used”. The last entry on this screen is called “More Test Limits…” This selection is a duplicate way of the F1 soft key to view all folders of test standards and select a standard that does not show up in the “Last Used” list.
 

3. バグ修正

  • Running an AUTOTESt with Impedance in it would cause the DTX CableAnalyzer to cycle its power after approx. 300 AUTOTESTs - Fixed.
  • Wire Map screen for 1000BASE-T incorrectly displayed. Measurement was good though – fixed.
  • ISO11801 Fiber Optic Link contains atten. coeff. values in the OTDR limits. These limits can causes good links to fail – it has been removed.

4. Known issues




Changes to DTX Version 2.06 (January 2008)

1.      Cable / Spec Database Change
  • Augmented Category 6 limits now labeled as Draft 8.0; limits are the same as Draft 6.0.
  • Added Fibre Channel Limits.
  • ISO/IEC 14763-3 Singlemode length is changed from 2,000 m to 5,000 m.
  • EN50173 Fiber Optic Link 1300 nm loss/km changed from 1.0 dB/km to 1.5 dB/km.
  • 100BASE-FX; fixed loss for 50/125 µm fiber at 1300 nm changed from 11.0 dB to 6.3 dB. This is reduced by 4.7 dB due to the coupling loss between the switch/hub and the 50/125 µm fiber.
  • 10BASE-FL; fixed loss for 50/125 µm fiber at 850 nm changed from 12.5 dB to 7.8 dB. This is reduced by 4.7 dB due to the coupling loss between the switch/hub and the 50/125 µm fiber.
  • ISO11801 Fiber Optic Link Attenuation coefficient values for these OTDR limits have been removed. Segment coefficent still remains.

2.     新機能

  • None. This is a maintenance release.

3.     バグ修正

  • Subtle changes to some limits, described above.

4.     Known issues 

  • With a test standard selected that has Impedance it in (Korean test limits for example) and  running approx 400 tests without saving them, the DTX cycles it's power. This will be fixed in the next release of DTX code, due end of June 2008.
  • If you have found an issue, please let us know.



Changes to DTX Version 2.04 (June 2007)

1.      Cable / Spec Database Change

  • Augmented Category 6 limits kept at Draft 6.0 - Draft 8.0 is out for comment now - limits are the same as Draft 6.0
  • Update for HCS cables including changing all cable names from “HCSxxxx” to DataLinkxxxx”
  • Added Mohawk cable names (15 cables)
  • Added Schrack Technik cable names (15 cables)
  • Added Siemens SIMATIC NET cable names (9 cables)
  • Changed ‘CAE GROUPE’ to ‘CAE Groupe’
  • Changed ‘ADC KRONE’ to ‘ADC’
  • Changed ‘DRAKA Comteq Multimedia’ to ‘DRAKA Comteq’
  • Renamed and updated many BKS cables names
  • Updated Kerpen cable names
  • The manufacturers’ database for fiber optic cables has been extensively modified, adding new fiber types and names, deleting obsolete fiber types and names and extending the database to support the plug-in OTDR module

2.     新機能 

  • Support for the new DTX Compact OTDR module
    The DTX Compact OTDR is a module that simply snaps onto a DTX mainframe transforming it into a fully functioning optical time domain reflectometer (OTDR) capable of testing both multimode and singlemode fiber. This powerful new module makes the DTX CableAnalyzer the only copper cable tester that can perform OTDR testing. This new capability will allow cable installers to transform their tester, their staff and ultimately their business with the ability to win new fiber jobs. This product introduction makes the DTX CableAnalyzer the only cable tester that can perform both Basic Loss Test fiber link certification (tier 1) and Extended fiber link certification (tier 2). The DTX Compact OTDR is designed for premises cabling technicians. Its revolutionary features will enable every technician to test like a fiber expert.

  • Additional warnings given about selecting AC Wire Map

  • Updated Support for the DTX-NSM, Network Service Module '

  • Expanded AC Wire Map Test Capability - now detects tip/ring reversals
    A DTX tester updated with software version 2.04 properly diagnoses (tip-ring) reversal errors in the pair wiring. This addition makes the AC wire map and its diagnostics fully equivalent to the commonly used dc wire map tests

3.     バグ修正 

  • Under very specific conditions during patch cord testing and the HDTDX is run, the DTX would reset itself - fixed. 
  • Using the DTX-NSM and Office ID Locators when pin 7 or 8 is open gave the incorrect ID number - fixed

4.     Known issues 








Changes to DTX Version 1.41 (February 2007)

1.      Cable / Spec Database Change

  • Augmented Category 6 limits updated to Draft 6.0.
  • Length limits on TSB-155, 10GBASE-T have been removed.
  • Draft numbers removed from TSB-155, this is now approved.
  • ISO Class Ea updated to 25N1255 with the 12 dB Lo IL added (If the normal Ea fails, you are allowed to use this)
  • TR24750 PL added.
  • IEC 14763-3 limit/procedure added.
  • Correct NVP for CommScope DataPipe 5EN5.
  • Create cable type for 50 ohm coax cable LDF4-50A.
  • Added Cat 6A UTP cable type.
  • Updated 3M cable type.
  • Updated ADC KRONE cable type.
  • Updated CAE-GROUPE cable type.
  • Added CEAM cable type.
  • Updated Corning cable type.
  • Updated Daetwyler cable type.
  • Added DRAKA cable type.
  • Added HCS cable type.
  • Added Molex cable type.
  • Added Spezialkabel München cable type.
  • Updated Systimax cable type.
  • Added Aug Cat6 as a cable type.
  • Gigabit Crossover Cable added to Outlet Configuration.
  • 15 m limits added to Patch Cord Databases.
  • Cable limits added under folder called "Other" to support Cable Manufacturers in their laboratories
     

2.     新機能 

  • AC Wire Map - allows you to test through a midspan PoE device (unique).
  • AutoSave feature added - inidcates which CableID you are testing on the front screen.
  • Trip counter feature on adapter count.
  • Grid lines added to plots - option in Tab 5 under Instrument Settings in SETUP.
  • Zoom up to x128 on vertical axis/change scale on vertical axis.
  • Vertical and horizontal zoom on graphs.
  • Rename a save Autotest result.
  • Improved Alien Crosstalk testing time - 19 secs - Please update to AxTalk Analyzer 2.1


3.     バグ修正 

  • DTX-GFM now allows custom fixed loss testing - fixed.
  • DTX-PLA001 will not occasionally calibrate- fixed.
  • FAIL light would always appear on remote unit when doing Alien Crosstalk testing - fixed.
  • DTX-NSM module didn't recognize the Hubbell PowerTRAC active patch panel as PSE - fixed.
  • Loading new settings from LinkWare takes too long – fixed.
  • Far End Source reference diagram wrong for Method B - fixed.

4.     Known issues 



Changes to DTX Version 1.4 (February 2007)

1.      This version was withdrawn immediately due to a bug in the diagnostic software which would cause the DTX to crash.
       We sincerely apologize for this inconvenience. Please update to Version 1.41.



Changes to DTX Version 1.31 (April 2006) 

1.      Bug Fix

  •  There was an error in the Korean setup which prevented two standards from being selected. Unless you are using the DTX CableAnalyzer with the language set to Korean, there is no need to upgrade from 1.3 to 1.31.



Changes to DTX Version 1.3 (February 2006) 
 

1.      Cable / Spec Database Change

  • There are no changes to Category 5e, 6. Class C, D, E or F these are ratified standards.
  • Updated Augmented Category 6 Limits to Draft 3.0 (New tighter Return Loss limit line for Perm. Link) If you are currently testing to TIA AugCat6 PL dr1.4, please consult your cable vendor/consultant/customer before updating the DTX CableAnalyzer. The limit has tightened by 2.0 dB for Return Loss. This is a draft standard and subject to further possible changes. We are committed to keeping the DTX current with TIA drafts. Once you have updated the DTX, it cannot be downgraded to a previous version.
  • Updated TSB-155 to Draft 3.0
  • Removed ISO AugCl Pl E 3N753 (ISO will not support Permanent Link testing at this time).
  • ISO AugCl CH E 3N753 changed to ISO Class Ea Channel.
  • Korean Emblem fiber test standards added.
  • KRONE cables changed to ADC.
  • New SYSTIMAX cables added.
  • New SIEMON cables added.
  • New ADC TrueNet fibers added.
  • New Gigamedia cables added.
  • Added support for LMR-400-75.
  • Panduit TX6000 LSZH set as UTP (was incorrectly set as FTP).
  • Ethernet Outlet Configuration now labeled Ethernet Two Pair to avoid confusion; to be used with 100BASE-TX test limit where 4,5 and 7,8 are not connected.

 
2.     新機能 

  • Support for the DTX-NSM Network Service Module.
  • Outlet Configuration now visible from main Autotest screen.
  • DTX used to prompt users with a message indicating Incompatible Settings, caused by selecting a Cable Type or Outlet Configuration not suitable for the chosen Test Limit. This will no longer happen. If you select TIA Cat 6 Perm. Link for example, it will not allow you to select Crossover as an Outlet Configuration. Incompatible Cable Types or Outlet Configurations are grayed out.
  • Recover deleted test results. If you saved results with Version 1.3 then inadvertently deleted results using your DTX CableAnalyzer, power down the unit, hold down keys F1 and EXIT, power up the DTX and let go of the keys once it has finished playing a tune. This function works for both the Internal Memory and any MMCs inserted using Version 1.3 code. It will not work if you formatted the MMC or have older code. For help in recovering results from formatted MMCs, please e-mail support@flukenetworks.com
  • Add setup item to force HDTDR and HDTDX to run with every test. You can find this in Tab 2 of SETUP. It will add approximately 6 seconds to each Autotest. HDTDX and HDTDR normally run on marginal passes or failures only. Since the DTX is so accurate, marginal passes could be with margins as low as 0.3 dB. If the margin is only 1.0 dB, HDTDX will not run and we will need to ask you to run HDTDX in Single Test to help you diagnose the cause of the low margin. Turning this feature on will help us to help you diagnose low margins better.
  • Extended the number of Cable IDs in the preset list from 253 to 2000.
  • Disable shield testing when selecting FTP or SSTP, requested by customers where the channel test has a UTP user cord. The status is shown on the main screen of the DTX so you know whether the shield is being tested or not.
  •  Warning message at end of Autotest for negative fiber loss results. If there is a negative loss of more than -0.09 dB, a warning will be given.
  • Loopback fiber module selftest added.
  • Rollover and Crossover added to Outlet Configuration.
  • Disable Wire Map Checking for Mid-span DTE Testing. Some Mid-span DTE devices do not pass through DC signals making it impossible for the DTX to complete a DC Wire Map measurement. Creating a custom test limit now lets you disable Wire Map checking.
  • Factory Clean you can restore your DTX to its original factory defaults. Rotate the dial to SPECIAL FUNCTIONS and select Self Test. Connector the main and remote units together, power on the remote unit. Press F3. Several warnings will be given. This will ERASE ALL SETTINGS and TEST RESULTS.


  3.     Bug fixes (Non of these affect the outcome of your test results) 

  • Wire Map Short circuit graphics misaligned.
  • Coax 10BASE-2, 10BASE-5 Prop Delay not present In Single Test.
  • UI screen continues to show old memory status after format until first save.
  • 自動テスト:remote beeps on Wire Map failure when audible tone disabled.
  • Coax looping TDR shows an invalid pair.
  • Length error when crossed wires.
  • Software update only looks for lowercase .dtx file.
  • Single Test HDTDR and HDTDX do not get Wire Map split pair notification.
  • FOM behavior inconsistent on some test limits when using SimpliFiber.
  • Fail star results not indicated by red asterisk.
  • When 0,00 format selected, the characters are joined.
  • Length pass/fail status should only be shown for shortest pair. This was a confusing screen, now only the shortest pair is indicated with either a pass or fail mark. The others are marked as i for information only.
  • Fiber power meter (monitor mode) change wavelength always starts at 850 nm.
  • Looping HDTDR/HDTDX can show clipped section.
  • Memory status improved after save.
  • Panduit TX6000 LSZH set as UTP (was incorrectly set as FTP).

  
  
 
Changes to Version 1.21 (August 2005)

  • Fixed bug causing DTX to reset itself if Impedance was a test parameter and certain lengths of cable tested. This bug only affect 10BASE-T, 100BASE-TX, 1000BASE-T and Korean test standards which contain the impedance test. 

  
  
Changes to Version 1.2 (June 2005) 

 1.      Cable / Spec Database Changes 

  • Updated Augmented Category 6 Limits Draft 1.4b
  • Updated TSB-155 Draft 1.3
  • New ISO 10GBASE-T Limits ISO TR24750 3N746
  • New Augmented Class E Limits 3N753
  • Added SYSTIMAX GigaSPEED X10D 1091A, 2091A & 2091A
  • DTX-PL Selftest ELFEXT limits corrected
  • Graybar VIP1000 & VIP2000 limits added (found under Vendor folder)
  • Chinese Limits added
  • Taiwan Limits added
  • Old Category 5 TSB-67 Limits added
  • Old ISO/IEC 11801 Class D (1995) Limit added


  2.     New languages 

  • Četina (Czech)
  • Polski (Polish)
  • Svenska (Swedish)
  • Traditional Chinese


3.     バグ修正 

  • DTX-PL Selftest ELFEXT limits corrected

  
Changes to Version 1.11 (April 2005)
 
  1.      Cable / Spec Database Changes 

  • Added Nexans and Brand-Rex twisted pair and fiber cables. The total number of cables is now 439.
  • The DTX-PL Selftest spec was reduced from 500MHz to 250MHz so it would run on the LT and 1200 versions.
  • Added the fiber type Multimode 62.5, MBW=220.
  • Added China standard (GBT) to DTX specs. These include GBT-Cat3 and GBT-Cat5 in a new China spec folder. These specs apply to both permanent link and channel link.
  • Added four new application specs for two pair POE (Power Over Ethernet). These include POE Cat 5e Channel, POE Cat 5e Link, POE Cat 6 Channel, and POE Cat 6 Link.
  • Deleted 1000BASE-SX/LX. Now is either 1000BASE-SX or 1000BASE-LX.
  • Deleted Backbone Laser MM. GFM now accepts TIA568 Backbone.


  2.     バグ修正 

  • "bad patch cord" message displayed incorrectly.
  • PL Self Test doesn't appear on DTX-1200 or LT. Scanning 1200 Main to LT Remote causes Lockup
  • Portuguese String Reported Too Long (No Truncation) -- Perform Special Functions-Set Reference-Module. After reference is set, press OK. The display's F1 is reported as too long.
  • Italian String Too Long -- On the Setup-Instrument Settings-Store Plot Data screen, the title is too long.
  • The following French strings are too long: a. special Functions-Set Reference-Module softkey F1. Note that the last "s" is truncated. b. perform the set reference and press OK. Again F1 is the culprit. Raccordement Note that the final "ent" is truncated.
  • Pressing TEST on remote when main is showing Wire Map warning fails to start test.
  • Extra attenuation of TDX if no length.
  • Looping Map/Resistance can't always find remote.
  • UI sometimes hangs/crashes during looping Map/Resistance.
  • Using a spec containing an '&' in the name causes setup to reset to defaults.
  • Fiber Type "FiberExpress 2000 (50) does not allow 10GBASE-S.
  • Top Summary Screen shows wrong margin for failing IL.
  • Return loss margin reported within the 3db rule range.

  
  
 
Changes from Version 1.0 to 1.1 (Januray 2005)

  1.    New features

  • Due to improvements in data processing methods, the following test times are now applicable: (it really is 9 secs for Cat 6)

    DTX CableAnalyzer Test Standards
     
    The speed of the NEXT, Return Loss measurements have not been altered, only the calculation process. Speeding up the NEXT, Return Loss measurements reduces the noise floor and dynamic range of the instrument which in turn compromises accuracy. 

     

  • New Autotest Results Screen. With many cabling vendors guaranteeing margins of performance, the DTX will now report the worst case margin for each parameter at the end of the Autotest. These values are reported in parenthesis:
     
    自動テストの結果 

     

  • Standards Database Updated
    The 10GBASE-T entries have been changed to reflect the new DRAFT 500 MHz requirement from the IEEE.
     
    Standards Database Updated Screen
     
    The 10GBASE-T CH Cl E 0-55m entry supports 10GBASE-T over existing category 6 / class E installations to 55 m. 10GBASE-T CH Cl E 55-100 m is for new UTP cabling systems designed specifically to eliminate Alien Crosstalk, the coupling of noise from one cable to the other. It also supports existing category 6 shielded cabling systems where Alien Crosstalk is not considered such as issue due to the shielding of the cable and connectors. In addition to this, you will find new entries in the TIA Folder:
     
    TIA Cat 3 Channel         TIA Cat 5 BL (TSB-95)
     
    TIA TSB-155 CH dr 1.1a is a channel measurement designed to verify the performance of an existing category 6 cabling system for 10GBASE-T operation. The same is for TIA TSB-155 PL dr 1.1a.
     
    TIA AugCat6 CH dr 2.0 is a channel measurement designed to certify new category 6 cabling systems designed to support 10GBASE-T over the full distance of 100 meters. The same is also for TIA AugCat6 PL dr 2.0, except this is a permanent link test where the distance is 90 meters.

     

  • TSB-95 has been added to support previous / existing category 5 installations. This is an obsolete standard, hence the BL (Basic Link) nomenclature.

     

  • VCSEL Fiber Option (DTX-GFM)
    For those who prefer to test with a VCSEL, there is now a VCSEL 850 nm / FP Laser 1310 nm option:
     
    DTX-GFM VCSEL Fiber Option
     
    This is for the verification of 1000BASESX or LX over multimode cable. If you require certification, you should continue to use your existing DTX-MFM module since the cabling standards specify the use of a category 1 light source.

     

  • ファイバー・オプティック・メーター
    Since we were unable to make the DSP-FOM work with the DTX, there is now a new power meter only module:
     
    ファイバー・オプティック・メーター
     
    For those wishing to carry out basic fiber testing, this is ideal. It can be used with an existing 850 nm, 1300 nm, 1310 nm or 1550 nm light source.

     

  • Battery Conditioner
    If your battery does not appear to last as long as it should or used to, it is probably dues to the internal gas gauge in the Li-ION battery drifting. To reset it, rotate the dial to SPECIAL FUNCTIONS and select Battery Status.
     
    Battery Status Screen
     
    Connect the testers together, plug in the power supplies and press the F1 Key. It is recommended to do this every six months. This will ensure maximum battery performance.

     

  • Coax Test
    Not just a coax test as with previous testers. This coax test includes insertion loss. The optional modules (DTX-CH003) are placed on the main and remote unit. Insertion Loss measurements can be made up to 350 meters.
     
    Coax Test - Insertion Loss
     
    The presentation on the adapter is F-Type with F-Type to BNC Adapters supplied to allow the testing of CCTV and 10BASE-2.

     

  • パッチ・コード・テスト
    Just as with the DSP-4x00, you can now certify patch cords with the optional DTX-PCU-6S.
     
    パッチ・コード・テスト 

     

  • Siemon TERA Adapters
    Only Fluke Networks DTX-1800 is approved to test the Siemon TERA Cabling system. Both Channel and Permanent Link Adapters are available.
     
    Siemon TERA Adapters 

     

  • Multiple Operator / Site Names. Just as with the DSP-4x00, you can now have up to 20 operator and site names in the DTX CableAnalyzer.

     

  • Automatic Module Detection.If only the fiber module is inserted, you will only get the fiber options menu. This is true for the optional coax module as well.

     

  • Custom Cable Type. If you have a vendor that is not in the cable library, you can create your own. Up to 9 custom cable types can be created.

     

  • Custom Test Limit Setup. You can now create your own cable tests based in existing tests. It is possible to remove certain test parameters. However, the standards name is prefixed and suffixed with an asterisk to indicate a custom cable test. This is true for fiber and copper tests but not for coax tests at this time.
     
    Custom Cable Test Setup 

     

  • Custom Outlet Configuration

     

  • Extended Frequency Option
    Although the category 5e standard stops at 100 MHz, we have received numerous requests for the measurement to continue to 350 MHz but keep the limit line standards compliant to 100 MHz. This is now possible by rotating the dial to SETUP and selecting Instrument Settings. Under Store Plot Data, you will see the following 3 options:
     
    Extended Frequency Option Screen
     
    No will mean that no plot data is stored. Standard will store plot data and Extended will store plot data to 350 MHz. This is also true if category 6 is selected. When class F and Extended are selected, the test will run to 900 MHz.

     

  • Scanning Function
    As with previous testers from Fluke Networks, the user has the ability to continuously measure a link for the parameters Wire Map and Resistance.
     
    Scanning Function 

     

  • HDTDX @ HDTDR Cursor Improved
     
    HDTDR Cursor Improved Screen 

     

  • HDTDX @ HTDR 4x Magnification. Using the F2 Key, you can now zoom on the vertical axis.

     

  • Permanent Link Field Calibration. Using the existing DSP-PLCAL Module and the new LinkWare 2.3, the DTX-PLA001 can now be calibrated, just as with the DSP-4x00 DSP-LIA101.

     

  • UL Verified Accuracy Bands Implemented. The region deemed as marginal has changed slightly to reflect the independently verified accuracy of the DTX by UL (Underwriters Laboratories). 

     

  • New Languages. Russian has now been added:
     
    New Languages Setup Screen

     

  • LinkWare Stats can now be exported to PDF. If you have LinkWare Stats installed, updating to LinkWare 2.3 will automatically install LinkWare Stats 1.2.

     

 

 

2.   Minor Bug Fixes 

  • 3 dB and 4 dB rule enabled in single test.
  • DTX does not reset during fault diagnostics if the link is 30 meters and fails the autotest now.
  • Stale test limits in Last Used list are deleted when software is updated.
  • Retain most recent test on power down.
  • SYSTIMAX 3071E in Cable Library had incorrect NVP. It has been changed to 69% from 68%. 
 

 

 

技術情報:- 10 Gigabit