Custom fixed loss with the DTX-MFM2 fiber adapter
Many specifiers hold installers to a higher standard than the approved cabling standards. It's not uncommon to see a fiber test specification with a fxied loss requirement. 問題ありません。The DTX CableAnalyzer can handle that. You just need to create a custom test limit.
If you are able to view YouTube, we have a video that will run you through the procedure.
If you are able to view YouTube, we have a video that will run you through the procedure.
Or follow these steps
- Rotate the dial on the DTX CableAnalyzer to SETUP.
- Select Fiber Loss and press ENTER.
- Select Test Limit and press ENTER.
- Press the F1 key for More.
- Select Custom and press ENTER.
- Press the F1 key to Create.
- Select Name Press ENTER.
- Enter the name you wish to call this custom test limit.
- Press SAVE when done.
- Select Use Default Values From and press ENTER.
- Press the Up Arrow key to select Application and press ENTER.
- Press the Up Arrow key to select General Fiber Optic and press ENTER.
- Change the Maximum Length.
- Change the Maximum Loss at 850 nm (1310 nm for singlemode)
- Change the Maximum Loss at 1300 nm (1550 nm for singlemode)
- Press SAVE.
- Select your new Custom Test Limit and press ENTER to select it.
- Rotate the dial to AUTOTEST.
For the correct referencing procedure, YouTube videos are also available: