ケーブリング・クロニクル
Shutting the Door on Dust
We know we talk a lot about fiber cleanliness, but let’s face it, contamination of fiber endfaces is still the number one cause of failures – regardless of much we harp on the topic.
You’ve probably often also heard comments surrounding the fact that dust caps are really just dust collectors. Thankfully, there are plenty of manufacturers out there that get it and have responded with shuttered fiber connectivity.
2019 年 4 月 1 日
The Making of an Expert Fiber Tester and Network Troubleshooter Part 2 of 3
Profile: Vangie Michenzi - (Read Part 1 of Vangie’s story)
Senior Fiber Optic Project Manager
BICSI Credentialed ITS Technician
Certified Data Center Designer and Installer
Advanced Communications Technology Services
2019 年 3 月 26 日
The Making of an Expert Fiber Testing and Network Troubleshooter Part 2 of 3
Part 2 of a three-part series
Profile: Vangie Michenzi
Senior Fiber Optic Project Manager
BICSI Credentialed ITS Technician
Certified Data Center Designer and Installer
Advanced Communications Technology Services
2019 年 3 月 25 日
企業向け単一ペア・イーサネットへの対応準備
最近、単一ペア・イーサネットと新しい 2 つの 10 Mb/s イーサネット規格が話題になっています。10 Mb/s は、一昔前の技術と考えられているかもしれません。実際、1990 年代に導入された 10BASE-T の通信速度が今日の LAN で使用されることはほとんどありません。しかし、従来の 10BASE-T とは異なり、最新の 10 Mb/s アプリケーションでは、低速度、低帯域幅の様々な IoT 機器を新しい方法で使用できる可能性があります。
2019 年 3 月 20 日
MPO 検査カメラの利点。| 製品マネージャーとのインタビュー
This week, Fluke Networks announced the FI-3000 Fiber Inspector Pro, designed for inspecting the end faces of Multiple Push-On (MPO) fiber connectors. We sat down with Carolyn Carter, the Senior Product Manager for
2019 年 3 月 12 日
Single-Mode Fiber is On Rise. 対応
Many of you are likely seeing an increased use of single-mode fiber among your customers due to several benefits (primarily distance and bandwidth), connection to carrier networks, and emerging single-mode applications in development.
2019 年 3 月 8 日
メタル線の効果的なトレース
When it comes to Tier 2 fiber testing, there are many smart people in our industry who can read an OTDR trace and pinpoint the type and location of a fault within the cable. And for those who might not be proficient in reading a trace, Fluke Networks’ OptiFiber Pro OTDR features advanced logic that automatically interprets the trace to provide a detailed and graphical map of events that includes the location of connectors, splices and anomalies.
2019 年 2 月 25 日
周極渦の到来!
This winter’s phenomenon popularly known as a “polar vortex” has kept many of us around the world under a blanket of snow and ice and well below freezing temps.
2019 年 2 月 20 日
ケーブル問題の原因
ツイスト・ペア配線障害の最も一般的な原因には、不適切な敷設、粗悪な部材(ケーブル、コネクター、パッチ・コードなど)、敷設ケーブルの損傷、テスターの誤ったセットアップなどがありますが、技術者は、リンクが不合格になった理由を正確に把握しなければならないことがあります。
テストで不合格になったパフォーマンス・パラメーターに基づいて、技術者はいくつかの原因を考察できます。詳しく見ていきましょう。
2019 年 2 月 13 日
束にするか否か
オーランドで開催された BICSI Winter Conference に最近出席し、業界誌を目にしたりウェビナーに参加された方であれば、PoE とケーブル・プラントへの影響について、たくさんの情報に触れたことと思います。リモート・デバイスに給電するケーブル束内の温度上昇や、それが挿入損失やケーブル劣化の原因となり、イーサネット伝送に影響を与えることなどなど、そろそろ聞き飽きたという方も多いかもしれません。